Skip to main content

Heat Recovery Outdoor Unit

The Bryant VRF 2-pipe heat recovery system is a combination of an outdoor unit with multiple style indoor units connected by refrigerant piping and wiring. Heat recovery outdoor unit lineup is a single module up to 28 tons, available as small and medium cabinet size.
Features

Product Features

  • Available in 6 – 28 ton non modular design
  • Industries most compact 20 ton VRF system
  • Ability to connect up to 64 indoor units
  • 2-pipe heat recovery system
  • High performance outdoor units with all inverter driven scroll compressor
  • DC inverter condenser fan motor
  • 208/230-3-60Hz or 460-3-60Hz voltage
  • Cooling ambient operating temperature is 14⁰ F to 122⁰ F and heating ambient operating temperature is -13⁰ F to 60⁰ F
  • Connected capacity is up to 150%

Reliability Features

  • All equipment wiring complies with NEC requirements
  • Unit constructed in accordance with ETL requirements
  • Unit performance is in accordance with AHRI 1230 standards
  • Compressor and condenser fan motor are inverter driven
  • Finned tube heat exchanger
  • Suitable for R-410a refrigerant

Installation Features

  • System utilizes 2 pipes to connect to multiport distribution controller(s)and up to 64 indoor units
  • Integrated controls design allows for complete system control
  • Single power connection for 28 ton systems
  • System utilize quick connect controls system
Specifications

Warranty

Effective 8/1/24, the warranty for our VRF equipment will include an opportunity for a 10-year parts and compressor limited warranty. If not registered within 90 days, the warranty will be a 5-year parts and 7-year compressor limited warranty.1 See warranty certificate for details.
 
1Except for residential applications in California and Quebec and other jurisdictions that prohibit warranty benefits conditioned on registration.

Product Features

  • Available in 6 – 28 ton non modular design
  • Industries most compact 20 ton VRF system
  • Ability to connect up to 64 indoor units
  • 2-pipe heat recovery system
  • High performance outdoor units with all inverter driven scroll compressor
  • DC inverter condenser fan motor
  • 208/230-3-60Hz or 460-3-60Hz voltage
  • Cooling ambient operating temperature is 14⁰ F to 122⁰ F and heating ambient operating temperature is -13⁰ F to 60⁰ F
  • Connected capacity is up to 150%

Reliability Features

  • All equipment wiring complies with NEC requirements
  • Unit constructed in accordance with ETL requirements
  • Unit performance is in accordance with AHRI 1230 standards
  • Compressor and condenser fan motor are inverter driven
  • Finned tube heat exchanger
  • Suitable for R-410a refrigerant

Installation Features

  • System utilizes 2 pipes to connect to multiport distribution controller(s)and up to 64 indoor units
  • Integrated controls design allows for complete system control
  • Single power connection for 28 ton systems
  • System utilize quick connect controls system