Preferred™ Variable-Speed Geothermal Heat Pump
Extra Savings, Extra Comfort, All Year Long
Our GP geothermal models deliver excellent energy efficiency and comfort thanks to their combination of two-stage compressor and variable-speed blower operation. Enjoy even temperatures, enhanced summer dehumidification and the dependability you expect from Bryant®.
- EER Efficiency Range :
- 15.5 to 24.5 EER (closed loop); 19.6 to 30.0 EER (open loop)
- COP Efficiency Range :
- 3.5 to 4.0 COP (closed loop); 4.0 to 4.6 COP (open loop)
- Compressor Type :
- Two-Stage
Features
- Manage your utility costs with high-efficiency comfort (efficiency is unit size dependent): Closed loop cooling EER - Up to 24.5; Closed loop heating COP - Up to 4.0
- Enjoy the ultra-quiet performance and even-temperature comfort of variable-speed air delivery
- Two-stage scroll compressor operation allows longer, more consistent cycles in lower stage for savings and comfort
- Superior summer dehumidification
- Insulated cabinet and compressor blanket for quiet operation
- Wide operating temperature range with exceptional cold weather performance
- Corrosion-resistant coil for durability
- 2" MERV 8 filtration
- 10-year parts and labor limited warranty1
- Supplemental, domestic hot water generation
- Internally-mounted auxiliary heat
- Smart startup add-on for smoother operation
1. To the original owner, when installed in a residence, a 10-year parts and labor limited warranty upon timely registration of equipment. Warranty period is 10 years on parts and 5 years on labor if not registered within 90 days of installation. Original owners residing in jurisdictions that prohibit warranty benefits conditioned on registration will automatically receive a 10-year parts and labor limited warranty. See warranty certificate for details.
Specifications
EFFICIENCY MANAGEMENT
Cooling Efficiency 15.5 to 24.5 EER (closed loop); 19.6 to 30.0 EER (open loop)
Heating Efficiency 3.5 to 4.0 COP (closed loop); 4.0 to 4.6 COP (open loop)
Heating and Cooling Two-stage operation for efficiency and comfort
ENERGY STAR® ENERGY STAR® qualified in all sizes
SOUND
Quiet Levels Quiet operation enhanced by full cabinet insulation; double-isolation compressor mounting and compressor sound blanket
CONVENIENCES
Filter Cabinet Built-in for easy filter changes
Maintenance Reminders With compatible control
TECHNOLOGY
Blower Motor High-efficiency variable-speed
Compressor Two-stage scroll
Control Board Microprocessor with compressor diagnostic capability
Refrigerant Puron® refrigerant
Refrigerant Management Thermostatic expansion valve
Protection Corrosion-resistant coil protection for long life
INSTALLATION
Positioning Vertical upflow, horizontal or vertical downflow units available
AESTHETICS
Capacity 2-6 tons
Construction Galvanized steel
Paint Baked-on urethane base coat and polyester top coat
Bryant reserves the right to discontinue or change any specification or design without prior notice or obligation.
- Manage your utility costs with high-efficiency comfort (efficiency is unit size dependent): Closed loop cooling EER - Up to 24.5; Closed loop heating COP - Up to 4.0
- Enjoy the ultra-quiet performance and even-temperature comfort of variable-speed air delivery
- Two-stage scroll compressor operation allows longer, more consistent cycles in lower stage for savings and comfort
- Superior summer dehumidification
- Insulated cabinet and compressor blanket for quiet operation
- Wide operating temperature range with exceptional cold weather performance
- Corrosion-resistant coil for durability
- 2" MERV 8 filtration
- 10-year parts and labor limited warranty1
- Supplemental, domestic hot water generation
- Internally-mounted auxiliary heat
- Smart startup add-on for smoother operation
1. To the original owner, when installed in a residence, a 10-year parts and labor limited warranty upon timely registration of equipment. Warranty period is 10 years on parts and 5 years on labor if not registered within 90 days of installation. Original owners residing in jurisdictions that prohibit warranty benefits conditioned on registration will automatically receive a 10-year parts and labor limited warranty. See warranty certificate for details.
EFFICIENCY MANAGEMENT
Cooling Efficiency 15.5 to 24.5 EER (closed loop); 19.6 to 30.0 EER (open loop)
Heating Efficiency 3.5 to 4.0 COP (closed loop); 4.0 to 4.6 COP (open loop)
Heating and Cooling Two-stage operation for efficiency and comfort
ENERGY STAR® ENERGY STAR® qualified in all sizes
SOUND
Quiet Levels Quiet operation enhanced by full cabinet insulation; double-isolation compressor mounting and compressor sound blanket
CONVENIENCES
Filter Cabinet Built-in for easy filter changes
Maintenance Reminders With compatible control
TECHNOLOGY
Blower Motor High-efficiency variable-speed
Compressor Two-stage scroll
Control Board Microprocessor with compressor diagnostic capability
Refrigerant Puron® refrigerant
Refrigerant Management Thermostatic expansion valve
Protection Corrosion-resistant coil protection for long life
INSTALLATION
Positioning Vertical upflow, horizontal or vertical downflow units available
AESTHETICS
Capacity 2-6 tons
Construction Galvanized steel
Paint Baked-on urethane base coat and polyester top coat
Bryant reserves the right to discontinue or change any specification or design without prior notice or obligation.
Documents