Evolution™ Split System Geothermal Heat Pump
A Preferred Match with Your High Efficiency Furnace or Fan Coil
The Bryant® GZA model offers high-efficiency geothermal cooling performance and is designed to be coupled with a gas/propane furnace or fan coil. It features a quiet, two-stage scroll compressor and, in the right combination, can allow you to enjoy the benefits of Hybrid Heat® technology to gain efficient geothermal heating before switching over to gas in colder weather.
- Energy Star :
- All sizes qualified
- EER Efficiency Range :
- Up to 25.1 EER (closed loop); 29.0 EER (open loop)
- COP Efficiency Range :
- Up to 4.6 COP (closed loop); 5.0 COP (open loop)
- Compressor Type :
- Two-Stage Scroll
Features
- Manage your utility costs with high-efficiency geothermal units (efficiency is unit size dependent)
- Two-stage scroll compressor operation allows longer, more consistent cycles in lower stage for savings and comfort
- Optimal dehumidification capability with the Evolution™ Connex™ Control
- Insulated cabinet and compressor blanket for quiet operation
- Wide operating temperature range with exceptional cold weather performance
- Compatible with a wide range of furnaces and fan coils
- Built in A2L dissipation fan system
- Smart startup add-on for smoother operation
- Passive dehumidification standard
- Corrosion-resistant coil protection for long life
- Lower global warming potential Puron Advance™ refrigerant
- Active Puron Advance™A2l dissipation sensor factory installed
- 10-year parts and 5-year labor limited warranty1
- Supplemental, domestic hot water generation
1. To the original owner, when installed in a residence, a 10-year parts and labor limited warranty upon timely registration of equipment. Warranty period is 10 years on parts and 5 years on labor if not registered within 90 days of installation. Original owners residing in jurisdictions that prohibit warranty benefits conditioned on registration will automatically receive a 10-year parts and labor limited warranty. See warranty certificate for details.
Specifications
EFFICIENCY MANAGEMENT
Cooling Efficiency Up to 25.1 EER (closed loop); 29.0 EER (open loop)
Heating Efficiency Up to 4.6 COP (closed loop); 5.0 COP (open loop)
Heating and Cooling Stages Two-stage operation for efficiency and comfort
Hybrid Heat® System Capable Allows gas furnace/heat pump system combination use for heating season
ENERGY STAR® ENERGY STAR® qualified in all sizes
SOUND
Quiet Levels Quiet operation enhanced by full cabinet insulation; double-isolation compressor mounting and compressor sound blanket
CONVENIENCES
Maintenance Reminders With the Evolution™ Connex™ Control
TECHNOLOGY
Blower Motor Dependent on furnace or fan coil paired with
Compressor Two-stage scroll
Control Board Microprocessor with compressor diagnostic capability
Refrigerant Puron Advance™
Refrigerant Management Thermostatic expansion valve
INSTALLATION
Placement Indoor
AESTHETICS
Capacity 2-6 tons
Construction Galvanized steel
Paint Baked-on urethane base coat and polyester top coat
Bryant reserves the right to discontinue or change any specification or design without prior notice or obligation.
- Manage your utility costs with high-efficiency geothermal units (efficiency is unit size dependent)
- Two-stage scroll compressor operation allows longer, more consistent cycles in lower stage for savings and comfort
- Optimal dehumidification capability with the Evolution™ Connex™ Control
- Insulated cabinet and compressor blanket for quiet operation
- Wide operating temperature range with exceptional cold weather performance
- Compatible with a wide range of furnaces and fan coils
- Built in A2L dissipation fan system
- Smart startup add-on for smoother operation
- Passive dehumidification standard
- Corrosion-resistant coil protection for long life
- Lower global warming potential Puron Advance™ refrigerant
- Active Puron Advance™A2l dissipation sensor factory installed
- 10-year parts and 5-year labor limited warranty1
- Supplemental, domestic hot water generation
1. To the original owner, when installed in a residence, a 10-year parts and labor limited warranty upon timely registration of equipment. Warranty period is 10 years on parts and 5 years on labor if not registered within 90 days of installation. Original owners residing in jurisdictions that prohibit warranty benefits conditioned on registration will automatically receive a 10-year parts and labor limited warranty. See warranty certificate for details.
EFFICIENCY MANAGEMENT
Cooling Efficiency Up to 25.1 EER (closed loop); 29.0 EER (open loop)
Heating Efficiency Up to 4.6 COP (closed loop); 5.0 COP (open loop)
Heating and Cooling Stages Two-stage operation for efficiency and comfort
Hybrid Heat® System Capable Allows gas furnace/heat pump system combination use for heating season
ENERGY STAR® ENERGY STAR® qualified in all sizes
SOUND
Quiet Levels Quiet operation enhanced by full cabinet insulation; double-isolation compressor mounting and compressor sound blanket
CONVENIENCES
Maintenance Reminders With the Evolution™ Connex™ Control
TECHNOLOGY
Blower Motor Dependent on furnace or fan coil paired with
Compressor Two-stage scroll
Control Board Microprocessor with compressor diagnostic capability
Refrigerant Puron Advance™
Refrigerant Management Thermostatic expansion valve
INSTALLATION
Placement Indoor
AESTHETICS
Capacity 2-6 tons
Construction Galvanized steel
Paint Baked-on urethane base coat and polyester top coat
Bryant reserves the right to discontinue or change any specification or design without prior notice or obligation.